Daikin FHYP60BV1 Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Aparelhos de ar condicionado "split system" Daikin FHYP60BV1. Split Sky Air Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 28
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
FHYP-B
Ceiling
Suspended Unit
technical data
Split
Sky Air
air conditioning systems
Vista de página 0
1 2 3 4 5 6 ... 27 28

Resumo do Conteúdo

Página 1 - Suspended Unit

FHYP-BCeiling Suspended Unittechnical data SplitSky Airair conditioning systems

Página 2 - Split - Sky Air

ELECTRICAL SPECIFICATIONSFor indoor units only: FHYP71BV1 FHYP100BV1 FHYP125BV1CURRENT Nominal running currentcooling/heatingA See chapters RP-L7/B7,

Página 3 - TABLE OF CONTENTS

3Dimensional drawingsFHYP35∼45BV1View from the front780 From the floor side 2500 or more(Required space)Note:1. Location of unit’s name plate: bottom

Página 4 - 2 steps 35∼125

FHYP100BV1View from the front780 From the floor side 2500 or more(Required space)Note:1. Location of unit’s name plate: bottom of fan housing inside t

Página 5

4Piping diagramsO Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipeIndoor heat exchangerField piping

Página 6

5Wiring diagrams3D027503-1FHYP35∼125BV11-RED, 2-WHITE, 3-BLACK33A Limit switch (swing flap)A1P Printed circuit boardC1R Capacitor (M1F)HAP Light emitt

Página 7

6Sound level6-1Sound level dataModelSound pressure levelSound power level (H)(cooling/heating)230VMeasuring location50HzH(cooling/heating)L(cooling/he

Página 8

FHYP71BV1FHYP125BV1Octave band center frequency (Hz)Octave band center frequency (Hz)Octave band sound pressure levelOctave band sound pressure levelH

Página 9

7Air flow patternsFHYP35-45BV1Cooling - air velocity distributionAir flow direction: horizontalFHYP35-45BV1Cooling - air temperature distributionAir f

Página 10 - Specifications

FHYP35-45BV1Heating - air velocity distributionAir flow direction: 45° (downward)FHYP35-45BV1Heating - air temperature distributionAir flow direction:

Página 11 - Dimensional drawings

FHYP60-71BV1Cooling - air velocity distributionAir flow direction: horizontalFHYP60-71BV1Cooling - air temperature distributionAir flow direction: hor

Página 12

Split - Sky AirEEDE03-1/2 • 03/2003Prepared in Belgium by Goekint GraphicsZandvoordestraat 300B - 8400 Ostend BelgiumInternet: http://www.daikineurope

Página 13 - Piping diagrams

FHYP60-71BV1Heating - air velocity distributionAir flow direction: 45° (downward)FHYP60-71BV1Heating - air temperature distributionAir flow direction:

Página 14 - Wiring diagrams

FHYP100BV1Cooling - air velocity distributionAir flow direction: horizontalFHYP100BV1Cooling - air temperature distributionAir flow direction: horizon

Página 15 - Sound level

FHYP100BV1Heating - air velocity distributionAir flow direction: 45° (downward)FHYP100BV1Heating - air temperature distributionAir flow direction: 45°

Página 16

FHYP125BV1Cooling - air velocity distributionAir flow direction: horizontalFHYP125BV1Cooling - air temperature distributionAir flow direction: horizon

Página 17 - 4D028550

FHYP125BV1Heating - air velocity distributionAir flow direction: 45° (downward)FHYP125BV1Heating - air temperature distributionAir flow direction: 45°

Página 18 - 4D028554

8Accessories8-1Standard accessoriesNamej1Drain hosej2Clampj3Washer for hanging bracketj4Clampj5Washer fixing plateQuantity 1 pc. 1 pc. 8 pcs. 6 pcs. 1

Página 19 - 4D028551

Specifications EKROROWire specificationsConnector (White)Whiteconnect to indoor PCB (X40A) connect to on/off switchAWG24 0.22mm2White* Input ’ON’ = cl

Página 20 - 4D028555

9Control systems9-1Wired remote control6.5 x 9 (Round end slit)Cover openCover closed5 x 7 (Round end slit)HoleJ55 x 10 (Round end slit)3TW23651-2BRC1

Página 21 - 4D028552

10Safety device settingsModel Safety devices 35 50 60 71 100 125FHYP-BV1Fuse −−−−−−Fan motor thermal fuse (°C) −−−−−−Fan motor thermal protector (°C)O

Página 22 - 4D028556

TABLE OF CONTENTSFHYP-B1 Features ... 22 Specifications...

Página 23 - 4D028553

1Features+ Leaves maximum floor and wall space for furniture, decorationand fittings+ Very compact casing (only 960 mm width)+ Extremely quiet in oper

Página 24 - 4D028557

2SpecificationsNOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FHYP35BV1 FHYP45BV1 FHYP60BV1NOMINAL INPUT Cooling kW - - 0.115Hea

Página 25 - Accessories

NOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FHYP71BV1 FHYP100BV1 FHYP125BV1NOMINAL INPUT Cooling kW 0.117 0.135 0.144Heating

Página 26

TECHNICAL SPECIFICATIONSFor indoor units only:INDOOR UNITS FHYP35BV1 FHYP45BV1 FHYP60BV1DIMENSIONS Unit H mm 195W mm 960 1,160D mm 680WEIGHT Unit kg 2

Página 27 - Control systems

TECHNICAL SPECIFICATIONSFor indoor units only:INDOOR UNITS FHYP71BV1 FHYP100BV1 FHYP125BV1DIMENSIONS Unit H mm 195W mm 1,160 1,400 1,590D mm 680WEIGHT

Página 28 - 11 Installation

ELECTRICAL SPECIFICATIONSFor indoor units only: FHYP35BV1 FHYP45BV1 FHYP60BV1CURRENT Nominal running currentcooling/heatingA See chapters RP-L7/B7, RY

Comentários a estes Manuais

Sem comentários