FCQ-B7
4-way Blow Ceiling
Mounted Cassette
(950mm x 950mm)
technical data
Split
Sky Air
air conditioning systems
Vista de página 0
1 2 3 4 5 6 ... 28 29

Resumo do Conteúdo

Página 1 - (950mm x 950mm)

FCQ-B74-way Blow CeilingMounted Cassette(950mm x 950mm)technical data SplitSky Airair conditioning systems

Página 2 - Split - Sky Air

3Dimensional drawingsFCQ35-71B7view A680 Suspension positionview B780 (Suspension position)860∼890 (Ceiling opening)Note:1. Location of unit’s name pl

Página 3 - TABLE OF CONTENTS

4Piping diagramsO Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipeHeat exchangerRefrigerant flowCoo

Página 4 - Optional Optional Optional

5Wiring diagrams3TW25086-1AFCQ35-60B733H Float switchA1P Printed circuit boardC1R Capacitor (M2F)F1U Fuse (5A, 250V)HAP Light emitting diode (service

Página 5 - Specifications

6Sound level6-1Sound level dataSound pressure level (dB)Sound pressure level (dB)Octave band center frequency (Hz)FCQ35-50B7 FCQ60-71B73TW22857-13TW22

Página 6

7Air flow patternsFCQ35B7Heating - air velocity distribution4-way discharge, air flow direction: downFCQ35B7Heating - air temperature distribution4-wa

Página 7

FCQ50B7Heating - air velocity distribution4-way discharge, air flow direction: downFCQ50B7Heating - air temperature distribution4-way discharge, air f

Página 8

FCQ60-71B7Heating - air velocity distribution4-way discharge, air flow direction: downFCQ60-71B7Heating - air temperature distribution4-way discharge,

Página 9

FCQ100-125B7Heating - air velocity distribution4-way discharge, air flow direction: downFCQ100-125B7Heating - air temperature distribution4-way discha

Página 10 - Dimensional drawings

8Branch duct connectionsFCQ-B71 branch duct - 3 way blowDischarge grill: K-DGSC4B (connection: diameter 150mm)Flexible duct K-FDK154B (connection: dia

Página 11 - Piping diagrams

FCQ-B71 branch duct - 2 way blowDischarge grill: K-DGSC4B (connection: diameter 150mm)Flexible duct K-FDK154B (connection: diameter 150mm, length: 4m)

Página 12 - Wiring diagrams

Split - Sky AirEEDE05-1/3 • 05/2005Prepared in Belgium by Goekint GraphicsZandvoordestraat 300B - 8400 Ostend BelgiumSpecifications are subject to cha

Página 13 - Sound level

FCQ-B72 branch duct - 2 way blowDischarge grill: K-DGSC4B (connection: diameter 150mm)Flexible duct K-FDK154B (connection: diameter 150mm, length: 4m)

Página 14 - 4D024116

FCQ-B71 branch duct - 3 way blowDischarge grill: K-DGSC4B (connection: diameter 200mm)Flexible duct: K-FDK154B (connection: diameter 200mm, length: 6m

Página 15 - 4D024117

FCQ-B71 branch duct - 2 way blowDischarge grill: K-DGSC4B (connection: diameter 200mm)Flexible duct: K-FDK154B (connection: diameter 200mm, length: 6m

Página 16 - 4D024118

FCQ-B72 branch duct - 2 way blowDischarge grill: K-DGSC4B (connection: diameter 200mm)Flexible duct: K-FDK154B (connection: diameter 200mm, length: 6m

Página 17 - 4D024119

9Accessories9-1Standard accessoriesCheck if the following accessories are included with your unit.Clamp1 pc.Also used as packing materialPaper pattern

Página 18 - Branch duct connections

9Accessories9-2Optional accessoriesOptionsItem Model FCQ35 FCQ50 FCQ60 FCQ71 FCQ100 FCQ125Decoration panel BYC125K7W1BFilter related High efficiency f

Página 19

FCQ-B7Fresh air intake kit1. Option kits KDDJ55B160, KDDJ55B160K,KDDJ55B160FFollowing restrictions must be kept:1. Maximum 20% of the nominal indoor u

Página 20

10Control systems10-1Wired remote control6.5 x 9 (Round end slit)Cover openCover closed5 x 7 (Round end slit)HoleJ55 x 10 (Round end slit)3TW23651-2BR

Página 21

11Center of gravityModel A BFCQ35-71B 230 90FCQ100-125B 288 1204TW22839-2B12 Safety device settingsModel Safety devices 35 50 60 71 100 125FCQ-BFuse(°

Página 22

13InstallationFCQ-B7Number Description1 Indoor unit2 Outdoor unit3 Remote control4 Inlet air5 Discharged air6 Refrigerant piping, connection electric

Página 23

TABLE OF CONTENTSFCQ-B71 Features ... 22 Specifications...

Página 24 - Accessories

1Features+ Leaves maximum floor and wall space for furniture, decorationand fittings+ Fits flush into each ceiling+ Extremely quiet in operation both

Página 25

2SpecificationsNOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FCQ35B7V1 FCQ50B7V1 FCQ60B7V1NOMINAL INPUT Cooling kW 0.140 0.140

Página 26

NOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FCQ71B7V3B FCQ100B7V3B FCQ125B7V3BNOMINAL INPUT Cooling kW 0.161 0.204 0.238Heati

Página 27 - Control systems

TECHNICAL SPECIFICATIONSFor indoor units only:INDOOR UNITS FCQ71B7V3B FCQ100B7V3B FCQ125B7V3BDIMENSIONS Unit H mm 230 288W mm 840D mm 840Decoration pa

Página 28 - 12 Safety device settings

ELECTRICAL SPECIFICATIONSFor indoor units only: FCQ35B7V1 FCQ50B7V1 FCQ60B7V1CURRENT Nominal running currentcooling/heatingA See chapters RS-B + RKS-D

Página 29 - Installation

ELECTRICAL SPECIFICATIONSFor indoor units only: FCQ71B7V3B FCQ100B7V3B FCQ125B7V3BCURRENT Nominal running currentcooling/heatingA See chapter RR-B7, R