Daikin FTYN35DV3B ATY35DV2 Especificações Página 11

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 10
Functions SiBE01-503
2 List of Function
1. Functions
Category Functions
FTYN25-35DV3B
RYN25-35DV3B
Category Functions
FTYN25-35DV3B
RYN25-35DV3B
Basic Function
Inverter (with Inverter Power Control)
Health & Clean
Air Purifying Filter with Bacteriostatic,
Virustatic Functions
Operation Limit for Cooling (°CDB)
15
~46
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
–10
~15
Air Purifying Filter with Photocatalytic
Deodorizing Function
PAM Control
Titanium Apatite Photocatalytic
Air-Purifying Filter
{
Compressor
Oval Scroll Compressor Longlife Filter
Swing Compressor Mold Proof Air Filter {
Rotary Compressor { Wipe-clean Flat Panel {
Reluctance DC Motor Washable Grille
Comfortable
Airflow
Power-Airflow Flap Mold Proof Operation
Power-Airflow Dual Flaps { Heating Dry Operation
Power-Airflow Diffuser Good-Sleep Cooling Operation
Wide-Angle Louvers {
Timer
Count up-down Timer {
Vertical Auto-Swing (Up and Down) { Night Set Mode {
Horizontal Auto-Swing (Right and Left)
Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure) {
3-D Airflow Self-Diagnosis (Digital, LED) Display
{
1
Comfort Airflow Mode Wiring Error Check
3-Step Airflow (H/P Only)
Anticorrosion Treatment of Outdoor Heat
Exchanger
{
Comfort Control
Auto Fan Speed {
Indoor Unit Silent Operation
Flexibility
Multi-Split / Split Type Compatible Indoor
Unit
Night Quiet Mode (Automatic)
Outdoor Unit Silent Operation (Manual) Flexible Voltage Correspondence
Intelligent Eye High Ceiling Application
Quick Warming Function Chargeless
2
Hot-Start Function { Either Side Drain (Right or Left) {
Automatic Defrosting { Power Selection
Operation
Automatic Operation {
Remote Control
5-Rooms Centralized Controller (Option)
Programme Dry Function {
Remote Control Adaptor
(Normal Open-Pulse Contact)(Option)
Fan Only {
Lifestyle
Convenience
New Powerful Operation (Non-Inverter) {
Remote Control Adaptor
(Normal Open Contact)(Option)
Inverter Powerful Operation
Priority-Room Setting DIII-NET Compatible (Adaptor)(Option)
Cooling / Heating Mode Lock
Remote
Controller
Wireless {
Home Leave Operation Wired
ECONO Mode
Indoor Unit On/Off Switch {
Signal Reception Indicator {
Temperature Display
Another Room Operation
Note:
{
: Holding Functions
: No Functions
1
:
2
:
Digital Only
7.5m(25 class), 10m(35 class)
Vista de página 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 127 128

Comentários a estes Manuais

Sem comentários